Need to accommodate the dynamic needs of your business in an incredibly easy and efficient way?

U-Flex Datacenter solutions are successfully fulfilling the requirements of cooling infrastructure that a data center set-up demands.Today’s technology-driven workplaces inclusive of data centers are synonymous with high-density equipment, virtualization and cloud computing strategies. These spaces require cooling infrastructure that can adapt to high and often fluctuating heat loads and simultaneously conserve energy. The complex data center setup too needs a full line of airflow management and in-floor cooling solutions.

U-Flex offers a range in-floor cooling products for data centers that minimize by-pass air and save energy. The directional airflow and variable-air-volume of these products in the data center promptly responds to any difference in utilization. They are also able to match cooling with the heat load at the rack level to provide desirable effects.

You can also avail the reasonably priced and yet effective airflow directed by fans to ease hot spots or implement high-density equipment in current raised floor facilities. A complete range of containment systems and air sealing grommets that cut down by-pass airflow, improve energy efficiency and increase data center capacity .

Steel Cementitious Panel

Anti Static Laminate Panel(server room, hub room and data centre)

Unitile's Steel Cementitious Flange Panels (600mm X 600mm) are non-combustible in nature and are coated with electrostatic epoxy paint. These panels consist of flat steel top sheet resistance welded to a formed steel bottom sheet, which is in filled with a lightweight proprietary cementitious mixture. Uniquely designed hemispherical reinforcing pockets on the underside enhance structural strength and deliver ultimate durability and acoustic performance

The cantilever edges of the panel are reduced and this unique product design enhances the technical performance of the system, reduces the risk of damage at site and aims to provide tremendous advantages to the user with respect to handling of panels and ease of installation during the construction program. Available in Corner Lock and Edge Support Rigid Grid System. Top performance finish in Bare and Carpet shade are available.

Grade Concentrated
Load Kgs
(lbf)
Ultimate
concentrated
Load Kgs
(lbf) (Min.)
Uniform
Distributed
Load Kgs / Sqmt
(lbf / sqft)
Rolling
Load* Kgs
(lbf)
USF - 800 363 (800) 907(2000) 1650 (338) 180 (397)
USF - 1000 454 (1000) 1134 (2500) 2025 (415) 225 (496)
USF - 1200 567 (1250) 1418 (3125) 2450 (502) 281 (619)
USF - 1500 680 (1500) 1701 (3750) 3100 (636) 315 (694)
USF - 2000 907 (2000) 1814 (4000) 3600 (738) 425 (937)
USF - 2500 1134 (2500) 2268 (5000) 4000 (820) 525 (1157)

Bare Panel - Unifold (Open office/Classroom)

Top performance finish in Bare and Carpet shade are available. Top performance finish in Bare and Carpet shade is available.Unitile latest generation of access floor panels designed using the all new folded flange technology to guarantee a squeak free floor for our users.Unitile’s Unifold Access Floor Panels are non-combustible in nature and are coated with electrostatic epoxy paint. These panels consist of flat steel top sheet resistance welded to a formed steel bottom sheet, which is in filled with a lightweight proprietary cementitious mixture. Uniquely designed hemispherical reinforcing pockets on the underside enhance structural strength and deliver ultimate durability and acoustic performance.

The uniqueness of this panel design is it engineered folded edges along the perimeter of the panel, which eliminates damage to the panel edges. Its wider beam width not only enhances the load carrying performance of the system but also provides a squeak free floor.

Grade Concentrated
Load Kgs
(lbf)
Ultimate
concentrated
Load Kgs
(lbf) (Min.)
Uniform
Distributed
Load Kgs / Sqmt
(lbf / sqft)
Rolling
Load* Kgs
(lbf)
UFP - 1650 360 (800) 1080 (2400) 1650 (340) 180 (400)
UFP - 2250 450 (1000) 1350 (3000) 2250 (464) 225 (500)

Calcium Sulphate Panel

Available in Corner Lock and Edge Support Rigid Grid System.Unitile Calcium Sulphate access flooring system is manufactured from 1600 Kg/ cubic meter density fibre reinforced Calcium Sulphate which forms the core of the panel. Non- combustible high quality alpha- hemihydrate single pressed gypsum and non-toxic unbleached cellulose fibers are used as reinforcing material. The base & top surface of the core is factory bonded using an appropriate combination of surface finishes such as Aluminum, Galvanized sheet steel, High Pressure Laminate etc. The edges of the panel are protected with a PVC edge band. The system offer an excellent acoustical sound deadening value.

Classification Deflection Concentrated Load Kgs/ KN
Class A 2.5 mm 900 / 8.8
Class B 3.0 mm 1000 / 9.8
Class C 4.0 mm 1200 / 11.76


Ultimate Concentrated Load 1500 Kgs / 14.7 KN
Uniformly Distributed Load/ Sq mtr 2900 Kgs/ 28.43 KN
Pedestal Axial Load Test 22 KN (2200 kgs) Axial Load per pedestal

TopStone Panel

Unitile's Raised Access Floor System is carefully fitted with Unitile's Topstone Floor Panels, which are designed to withstand extreme weight and pressure. Unitile's Topstone access floor panels (600x600mm) comprise of customer selected Vitrified or any Natural Stones tiles which are factory bonded to the steel cementitious access floor panel with propriety admixed glue to ensure perfect bonding of two different substrate.

The edges of the tile and the panel are protected with a sleek, visually appealing PVC edged trim with engineered degree to ensure protection of the stoned edges on all four sides. The edged trim is thermostatically factory bonded with high strength heat resistance adhesive to minimize detachment.

Grade Concentrated
Load Kgs
(lbf)
Ultimate
concentrated
Load Kgs
(lbf) (Min.)
Uniform
Distributed
Load Kgs / Sqmt
(lbf / sqft)
Rolling
Load* Kgs
(lbf)
UTS Heavy Grade 675 (1500) 1690 (3755) 2025 (419) 315 (690)

Chipboard Panel

Chipboard Encapsulated Panel

Unitile's Chipboard Encapsulated Access Floor Panel consists of engineered 600mm square modular panels constructed around a high density E1 grade chipboard core. The core is fully encapsulated with GI on all six sides in a special mechanical interlocking of the top & bottom GI tray. This double folded lock constructs into a panel that has a unique in-built stringer at the underside of each panel edge. This unique engineering exhibits fine dimensional tolerances for modular control, accurate alignment of grids & inter-changeability of panels that complies with the Euro Class requirement of EN 12825.

Classification Deflection Concentrated Load Kgs/ KN
Class A 2.5 mm 544 / 5.34
Class B 3.0 mm 608 / 5.96
Class C 4.0 mm 726 / 7.12

Chipboard Non Encapsulated Panel

Unitile's Chip Board Non Encapsulated Panel consists of engineered 600mm square modular panels constructed around a high density E1 grade chipboard core. The system fully complies with the Euro Class requirement of EN 12825.The base and the top surface of the core is factory bonded using an appropriate combination of surface finishes such as Aluminum, Galvanized sheet steel, High Pressure Laminate etc. The surface coverings are trimmed to ensure fine dimensional control, accurate alignment of grids and inter-changeability of panels. A full depth ABS edge band provides total encapsulation of the chipboard core and also protects the edge of the surface covering to prevent ingress of moisture.

Electrical continuity is maintained through the top and bottom surface of the panel on to the pedestal head through conductive gasket. This ensures positive positioning and location of the floor panel on to the understructure system.

Classification Deflection Concentrated Load Kgs/ KN
Class A 2.5 mm 544 / 5.34
Class B 3.0 mm 608 / 5.96
Class C 4.0 mm 726 / 7.12

Air Flow Grills

Just sit right back and you'll hear a tale a tale of a fateful trip that started from this tropic port aboard this tiny ship all of them had hair of gold like their mother the youngest one in curls. Space. The final frontier.

Air Plugs

MultipliYair

Just sit right back and you'll hear a tale a tale of a fateful trip that started from this tropic port aboard this tiny ship all of them had hair of gold like their mother the youngest one in curls. Space. The final frontier.

Air Flow Grills

Air Plugs

U-Flex Air Plugs 101

ings in new raised floor cutouts require sealing before installation of communications or power cabling. Integral grommet is equipped to effectively address this concern in the most reliable manner. As per estimates comprehended at multiple data centers, unsealed floor ings prevent close to 48% of conditioned air from having access to IT equipment. Loss of air in this manner generally termed as bypass airflow results in IT equipment hot spots, cooling unit inadequacies and mounting infrastructure costs. U-Flex products are designed as the perfect solution to discourage bypass airflow and its consequences with respect to data center cooling.

U-Flex Air Plugs 303

Seals ings in raised floor cutouts already installed where communications or power cabling have been established previously. Floor ings, if left , generally obstruct 48% of conditioned air from reaching IT equipment. Loss of air in this manner generally termed as bypass airflow results in IT equipment hot spots, cooling unit inadequacies and mounting infrastructure costs. Products designed by U-Flex restrict this bypass airflow and minimize negative effects on data center cooling.

U-Flex Air Plugs 202

Used to seal different types of raised floor tile cutouts. It also facilitates the desired flexibility needed for removing tiles without the risk of cables getting entangled. Floor ings, if left , generally obstruct 48% of conditioned air from reaching IT equipment. Loss of air in this manner generally termed as bypass airflow results in IT equipment hot spots, cooling unit inadequacies and mounting infrastructure costs. Products designed by U-Flex restrict this bypass airflow and minimize negative effects on data center cooling.

U-Flex Air Plugs 203

Surface Mount large grommet has larger sealing capacities. It acts as a closure for different types of raised floor tile cutouts already in use at premises and facilitates the desired flexibility needed for removing tiles without the risk of cables getting entangled.

U-Flex Air Plugs 204

Surface Mount large grommet has larger sealing capacities. It acts as a closure for different types of raised floor tile cutouts already in use at premises and facilitates the desired flexibility needed for removing tiles without the risk of cables getting entangled.

U-Flex Air Plugs 012

Ideal to be used for sealing a wide variety of new as well as existing ings . It also provide the flexibility to seal huge ings (e.g. those under PDUs). As per measurements taken at various data centers, as much as 60% of conditioned air cannot reach the air intake of IT equipment due to uncapped floor ings. Loss of air in this manner generally termed as bypass airflow results in IT equipment hot spots, cooling unit inadequacies and mounting infrastructure costs. Products designed by U-Flex restrict this bypass airflow and minimize negative effects on data center cooling.

U-Flex Air Plugs 013

Ideal to be used for sealing a wide variety of new as well as existing ings . It also provide the flexibility to seal huge ings (e.g. those under PDUs). As per measurements taken at various data centers, as much as 60% of conditioned air cannot reach the air intake of IT equipment due to uncapped floor ings. Loss of air in this manner generally termed as bypass airflow results in IT equipment hot spots, cooling unit inadequacies and mounting infrastructure costs. Products designed by U-Flex restrict this bypass airflow and minimize negative effects on data center cooling.

U-Flex Air Plugs G50

Its function is to seal ings in new as well as existing raised floor cutouts to control bypass airflow and maximize cooling system efficiency. The 3″ Round Grommet features Brush Technology that defines its image as a premium solution for your data center. This innovative sealing technology cut down costly bypass airflow down to bare minimum, increases usable cooling unit capacity and maximizes efficiency from HVAC equipment.

U-Flex Air Plugs G100

Its function is to seal ings in new as well as existing raised floor cutouts to control bypass airflow and maximize cooling system efficiency. The 4″ Round Grommet features Brush Technology that defines its image as a premium solution for your data center. This innovative sealing technology cut down costly bypass airflow down to bare minimum, increases usable cooling unit capacity and maximizes efficiency from HVAC equipment.

Vison Panel

Vision Panel is constructed with an overall dimension of 600x600mm. The viewing area is made of toughened glass available in sizes of 300x300mm, 450x450mm and 500x500mm. The Vision Panel can be used for viewing critical points that need frequent monitoring and is designed for normal walking load only.

Panel Lifter

Unitile’s double cup suction panel lifter(s) allows panels to be lifted quickly, easily and safely without damaging any of the adjoining access floor panels. Not only are they more efficient and safer than using improper tools (screwdrivers, knives), using them will also extend the life of your raised floor. Unitile’s panel lifters are designed for use on all access floor panels which includes 'bare' and 'high pressure laminate' panel surfaces.

Electroflex

Electroflex is a concealed electrical monument box which has a depth of 70mm to accommodate plug-in facility and 35mm depth to accommodate power, voice and data (PVD) accessories. The hinge lid is constructed with pre-coated galvanized steel and has recessed grey ABS trim to accommodate carpet tiles or any other factory bonded finish to match the adjacent floor finish.

Ramp Shoe

The product is made up of heavy-duty anodized aluminum. The Ramp Shoe features a trapezoid anchoring leg, which is firmly secured to the concrete floor. The system is securely fastened to the concrete floor at regular intervals with the use of fasteners. The ramp provides a sloped transition surface that terminates at the height of the access floor tile edge. The profile protects tile edges to eliminate trip hazards and ensures easy access of trolleys.

MultiplYair

MultiplYair U-flex – MultiplYair cooling system is used in high and medium density data centre which always faces unique cooling challenges. There is a considerable increase in the consumption of energy while attempting to cool a few selective racks which often leads to excessive.